Main parameters
|
Equipment size
|
2180 (length) × 915 (width) × 1270 (high) (mm) ± 1%
|
Channel size
|
650 (W) x 500 (H) (mm) ± 1%
|
The size of the frame
|
1240 (length) × 750 (width) × 650 (high) (mm) ± 1%
|
Conveyor belt speed
|
0.2 ±0.02 m/s
|
conveyor belt uniform load
|
200 kg
|
Conveyor with a single package
|
the maximum weight 20KG
|
single check dose
|
<1.2μGy
|
Resolution
|
diameter 0.0787mm metal wire
|
penetrating force
|
40mm steel plate
|
Film safety
|
safety of ISO1600 film
|
Leakage dose
|
<0.11μGy / h (national standard is not greater than 5μGy / h)
|
X-ray generator
|
Beam direction
|
bottom illuminated
|
tube current
|
0.4~1.2mA (adjustable)
|
Tube voltage
|
100~160 kV (adjustable)
|
radiation beam divergence angle
|
80 °
|
Cooling / working cycle
|
sealed oil cooled / 100%
|
Image processing system
|
X-ray sensor
|
L-shaped photodiode detector (Japan imported)
|
Display
|
19-inch high-definition liquid crystal display
|
Image display
|
24-bit true color, image enhancement, edge enhancement, high energy high wear, high energy low wear. Image is zoomed in, the image is darkened, the image is pulled back, the image is automatically saved. Multi-energy penetration, organic display is orange, inorganic display is blue, the mixture is shown in green
|
Use the environment
|
Working temperature / humidity
|
-10 ℃ ~ 45 ℃ / 10% ~ 95% (no condensation)
|
Storage temperature / humidity
|
-20 ℃ ~ 60 ℃ / 10% ~ 95% (no condensation)
|
Working voltage
|
220VAC (± 10%) 50 ± 3Hz
|
Power loss
|
0.7KW (max)
|
Noise level
|
≤ 58dB
|
Other functions
|
Picture storage capacity of more than 500 million, and can call any print
|
Dangerous goods prompt function
|
line packet counting function
|
A key off function
|
dynamic screen switching function
|
Environmental protection lead curtain, to avoid lead pollution
|
external U disk interface, aspect of the picture
|
Ray source automatic adjustment procedure
|
operator identification program
|